OVERVIEW
The ONV-IPS33026FM is a full gigabit managed industrial Ethernet fiber switch independently developed by ONV. It has 24*10/100/1000Base-T RJ45 ports and 2*100/1000Base-X SFP fiber slot ports (Combo port). Each port can support wire-speed forwarding.
The ONV-IPS33026FM has L2+ full network management function, supports IPV4/IPV6 management, static route full line rate forwarding, complete security protection mechanism, complete ACL/QoS policy, and rich VLAN functions, and is easy to manage and maintain. Supports multiple network redundancy protocols STP/RSTP/MSTP (<50ms) and (ITU-T G.8032) ERPS (<20ms) to improve link backup and network reliability. When a one-way network fails, communication can be quickly restored to ensure important Uninterrupted communication for applications. According to the actual application requirements, you can configure multiple application services such as port traffic control, VLAN division, and SNMP through the Web network management mode. It meets the needs of various industrial Ethernet application environments and is suitable for industrial, intelligent transportation, rail transit, power industry, mining, petroleum, marine, metallurgical, and green energy construction to form a cost-effective, stable and reliable communication network.
FEATURE
Gigabit access, Gigabit SFP port uplink
◇ Support non-blocking wire-speed forwarding.
◇ Support full-duplex based on IEEE802.3x and half-duplex based on Backpressure.
◇ A combination of Gigabit Ethernet port and Gigabit SFP port to meet the networking requirements of various scenarios.
Strong business processing capability
◇ STP/RSTP/MSTP.
◇ Static and dynamic aggregation.
◇ IGMP V1/V2 and IGMP Snooping.
◇ IEEE802.1Q VLAN, flexible VLAN division, Voice VLAN, and QinQ configuration.
◇ QoS, Priority mode based on 802.1P, Port & DSCP, queue scheduling algorithm including EQU, SP, WRR & SP+WRR.
◇ ALC, filter data packet through configuring matching rules, processing operation & time permission, and provide flexible and safe access control.
Security
◇ 802.1X authentication.
◇ Port isolation,Storm control.
◇ IP-MAC-VLAN-Port binding.
Stable and reliable
◇ Low power consumption, No fan, aluminum shell.
◇ Self-developed power supply, high redundancy design, providing a long term and stable power output.
◇ CCC,CE, FCC, RoHS.
◇ The user-friendly panel can show the device status through the LED indicator of PWR, Link.
DIMENSION
ORDERING INFORMATION
Model |
Description |
Recommended Power |
ONV-IPS33026FM |
L2+ managed industrial Ethernet fiber switch with 24*10/100/1000M RJ45 ports and 2*100/1000M SFP ports (Combo port). Built-in redundant dual power supply. support 2AC+DC power terminal input and 1U/19-inch cabinet installation. |
2*60W |
Note: The industrial Ethernet switch is not included SFP optical module by default and needs to be purchased separately. |
PACKING LIST
PACKING LIST |
CONTENT |
QTY |
UNIT |
26-port full gigabit managed industrial Ethernet fiber switch |
1 |
SET |
|
AC Power Cable |
1 |
PC |
|
Mounting Kits |
1 |
SET |
|
User Guide |
1 |
PC |
|
Warranty Card |
1 |
PC |
OPTICAL MODULE
Product |
Model |
Description |
Unit |
1.25G Optical Module
|
2630-G |
Industrial SFP optical module, 1.25G, multi-mode dual fiber 850nm, transmission distance: 550m, LC interface, support DDM function, support hot plug and pull. |
PC |
2632-G |
Industrial SFP optical module, 1.25G, single-mode dual fiber 1310nm, transmission distance: 20km, LC interface, support DDM function, support hot plug and pull. |
PC |
|
2612-T-G |
Industrial SFP optical module, 1.25G, single-mode single fiber TX1310nm/RX1550nm, transmission distance: 20km, LC interface, support DDM function, support hot plug and pull. |
PC |
|
2613-R-G |
Industrial SFP optical module, 1.25G, single-mode single fiber TX1550nm/RX1310nm, transmission distance: 20km, LC interface, support DDM function, support hot plug and pull. |
PC |
|
2612-T-G-SC |
Industrial SFP optical module, 1.25G, single-mode single fiber TX1310nm/RX1550nm, transmission distance: 20km, SC interface, support DDM function, support hot plug and pull. |
PC |
|
2613-R-G-SC |
Industrial SFP optical module, 1.25G, single-mode single fiber TX1550nm/RX1310nm, transmission distance: 20km, SC interface, support DDM function, support hot plug and pull. |
PC |
|
Power Module |
2633 |
1.25G SFP optical module transfers to 10/100/1000M RJ45 port. |
PC |
RELATED PRODUCT
Model |
Description |
ONV-IPS33018FM |
L2+ managed industrial Ethernet fiber switch with 16*10/100/1000M RJ45 ports and 2*100/1000M SFP slot ports. Built-in redundant dual power supply. Support 2AC+DC power terminal input and 1U/19-inch cabinet installation. |
ONV-IPS36028FM |
L2+ managed industrial Ethernet switch with 24* 10/100/1000M RJ45 ports and 4*1/10G uplink SFP+ fiber slot ports. Built-in redundant dual power supply. Support 2AC+DC power terminal input and 1U/19-inch cabinet installation. |
ONV-IPS36036FM |
L2+ managed industrial Ethernet switch with 24* 10/100/1000M RJ45 ports and 8*100/1000M uplink SFP fiber slot ports and 4*1/10G uplink SFP+ fiber slot ports. Built-in redundant dual power supply. Support 2AC+DC power terminal input and 1U/19-inch cabinet installation. |
ONV-IPS36368FM |
L2+ managed industrial Ethernet switch with 8* 10/100/1000M RJ45 ports and 24*100/1000M uplink SFP fiber slot ports and 4*1/10G uplink SFP+ fiber slot ports. Built-in redundant dual power supply. Support 2AC+DC power terminal input and 1U/19-inch cabinet installation. |
ONV-IPS36448FM |
L2+ managed industrial Ethernet switch with 12* 10/100/1000M RJ45 ports and 28*100/1000M uplink SFP fiber slot ports and 4*1/10G uplink SFP+ fiber slot ports. Built-in redundant dual power supply. Support 2AC+DC power terminal input and 1U/19-inch cabinet installation. |
TECHNICAL SPECIFICATION
Model |
ONV-IPS33026FM |
Interface Characteristics |
|
Fixed Port |
2*AC100-240V input ports Alarm switch port (FAULT) 1*Console port (115200, N, 8,1) 24*10/100/1000Base-T RJ45 ports (Data) 2*100/1000Base-X uplink SFP slot ports(Data)(Combo port) 1 group of DC12-48V input ports (Support reverse polarity protection function) |
Ethernet Port |
Port 1-24 support 10/100/1000Base-T(X) auto-sensing,full/half duplex MDI/MDI-X self-adaption |
Twisted Pair Transmission |
10BASE-T: Cat3,4,5 UTP(≤100 meter) 100BASE-TX: Cat5 or later UTP(≤100 meter) 1000BASE-T: Cat5e or later UTP(≤100 meter) |
SFP Slot Port |
Gigabit SFP optical fiber interface, default not included optical modules (optional order single-mode / multi-mode, single fiber/ dual fiber optical module. LC) |
Optical Cable/ Distance |
Multi-mode: 850nm/0-500M, Single-mode:1310nm/ 0-40KM, 1550nm/ 0-120KM. |
Chip Parameter |
|
Network Management Type |
L2+ |
Network Protocol |
IEEE802.3 10BASE-T, IEEE802.3i 10Base-T, IEEE802.3u 100Base-TX IEEE802.3ab 1000Base-T, IEEE802.3z 1000Base-X, IEEE802.3x |
Forwarding Mode |
Store and Forward(Full Wire Speed) |
Switching Capacity |
256Gbps |
Forwarding Rate@64byte |
38.69Mpps |
MAC |
8K |
Buffer Memory |
8M |
Jumbo Frame |
9.6K |
CPU(Hz) |
416MHz |
DRAM |
1G |
Flash |
128M |
LED Indicator |
Power:PWR (Yellow), System: SYS(Yellow), Network: Link (Yellow), Fiber port: L/A (Green) |
Reset Switch |
Yes, Press and release for 10 seconds to restore factory settings |
Power Supply |
|
Total PWR / Input Voltage |
60W (AC100-240V) |
Power Consumption |
Standby<18W, Full load<35W |
Power Supply |
Built-in power adapter, AC100~240V 50-60Hz 0.56A |
Power Input Port |
1 group of DC12-48V input port, Alarm switch port, 2* AC power input ports Dual input power port design: AC power supply priority, support anti-reverse protection, power-off automatic switching DC connection. |
Physical Parameter |
|
Operation TEMP / Humidity |
-40~+80°C, 5%~90% RH Non condensing |
Storage TEMP / Humidity |
-40~+85°C, 5%~95% RH Non condensing |
Dimension (L*W*H) |
440*298*44mm |
Net /Gross Weight |
<4.7kg / <5.4kg |
Installation |
Desktop, 19 inch 1U cabinet |
Certification & Warranty |
|
Lightning Protection |
Lightning protection: 6KV 8/20us, Protection level: IP40 IEC61000-4-2(ESD):±8kV contact discharge,±15kV air discharge IEC61000-4-3(RS):10V/m(80~1000MHz) IEC61000-4-4(EFT): power cable:±4kV; data cable:±2kV IEC61000-4-5(Surge):power cable:CM±4kV/DM±2kV; data cable:±4kV IEC61000-4-6(radio frequency transmission):10V(150kHz~80MHz) IEC61000-4-8(power frequency magnetic field):100A/m;1000A/m ,1s to 3s IEC61000-4-9(pulsed magnet field):1000A/m IEC61000-4-10(damped oscillation):30A/m 1MHz IEC61000-4-12/18(shockwave):CM 2.5kV,DM 1kV IEC61000-4-16(common-mode transmission):30V; 300V,1s FCC Part 15/CISPR22(EN55022):Class B IEC61000-6-2(Common Industrial Standard) |
Mechanical Properties |
IEC60068-2-32 (free fall), IEC60068-2-27 (anti shock) IEC60068-2-6 (anti vibration) |
Certification |
CCC, CE mark, commercial, CE/LVD EN62368-1, FCC Part 15 Class B, RoHS |
Warranty |
5 years, lifelong maintenance. |
Network Management Features |
|
Interface |
IEEE802.3X (Full-duplex) Broadcast storm control based on port speed The speed limit of the message flow in the access port. The minimum particle size is 64Kbps. Port temperature protection setting Port green Ethernet Energy-saving setting |
Layer 3 Features |
L2+ network management ARP protocol, maximum 1024 entries IPV4/IPV6 static route/default route supports up to 128 entries Layer 3 routing and forwarding, support communication between different network segments and different VLANs |
VLAN |
Port configuration of Access, Trunk, Hybrid VLAN based on MAC,VLAN based on the protocol Voice VLAN, QinQ configuration,4K VLAN based on port, IEEE802.1q |
Port Aggregation |
LACP, Static aggregation Max 14 aggregation groups and 8 ports per group. |
Spanning Tree |
STP (IEEE802.1d), RSTP (IEEE802.1w), MSTP (IEEE802.1s) |
Industrial Ring Network Protocol |
G.8032 (ERPS),Recovery time less than 20ms 255 Ring at most, Max 254 devices per ring. |
Multicast |
MLD Snooping v1/v2,Multicast VLAN IGMP Snooping v1/v2, Max 1024 multicast groups, Fast log out |
Port Mirroring |
Bidirectional data mirroring based on port |
QoS |
Flow-based Redirection, Flow-based Rate Limiting Queue Scheduling Algorithm (SP, WRR, SP+WRR) Flow-based Packet Filtering, 8*Output queues of each port 802.1p/DSCP priority mapping, Diff-Serv QoS, Priority Mark/Remark |
ACL |
Port-based Issuing ACL,ACL based on port and VLAN L2 to L4 packet filtering, matching first 80 bytes message. Provide ACL based on MAC, Destination MAC address, IP Source, Destination IP, IP Protocol Type, TCP/UDP Port, TCP/UDP Port Range, and VLAN, etc. |
Security |
IEEE802.1X & MAC address authentication Broadcast storm control, Backup for host datum SSH 2.0, SSL, Port isolation, ARP message speed limit User hierarchical management and password protection IP-MAC-VLAN-Port binding, ARP inspection, Anti-DoS attack AAA & RADIUS, MAC learning limit, Mac black holes, IP source protection |
DHCP |
DHCP Client, DHCP Snooping, DHCP Server, DHCP Relay |
Management |
CPU instant utilization status view One-key recovery, Cable Diagnose, LLDP Console /AUX Modem /Telnet /SSH2.0 CLI Web Management (HTTPS), NTP, System work log, Ping Test Download & Management on FTP, TFTP, Xmodem, SFTP, SNMP V1/V2C/V3 ONV NMS-Smart Network Management System Platform (LLDP+SNMP) |
System |
Category 5 Ethernet network cable Web browser: Mozilla Firefox 2.5 or higher, Google browser chrome V42 or higher, Microsoft Internet Explorer10 or later. TCP/IP, network adapter, and network operating system (such as Microsoft Windows, Linux, or Mac OS X) installed on each computer in a network |