OVERVIEW
ONV-IoT7000-SW6G2F-DG is a Gigabit AI managed industrial switch independently developed by ONV. It has 6*10/100/1000Base-T adaptive RJ45 ports and 2*100/1000Base-X SFP optical ports. Each port can support wire-speed forwarding.
ONV-IoT7000-SW6G2F-DG is a managed switch designed for intelligent O&M box networking. It has rich L2+ network management functions, POE expansion, and AI management functions. The industrial switch adopts a flat DIN-rail structure which can be directly installed in the industrial control box, security monitoring box, power control box, traffic control box, control cabinet, and light pole control box.
ONV-IoT7000-SW6G2F-DG supports IPV4/IPV6 management, static routing and forwarding, complete security protection mechanism, complete ACL/QoS strategy, and rich VLAN functions, which are easy to manage and maintain. Support a variety of network redundancy protocols STP/RSTP/MSTP (<50ms) and (ITU-T G.8032) ERPS (<20ms) to improve link backup and network reliability. When a unidirectional network fails, it can be quickly restored Communication guarantees uninterrupted communication for important applications. According to actual application needs, various application service configurations such as port management, routing address management, port flow control, VLAN division, IGMP, and security policies are carried out through network management methods such as Web, SNMP, and Telnet. The switch completely follows the design and materials of industrial products. The shell is made of aluminum alloy to enhance heat dissipation efficiency. It has excellent industrial site environmental adaptability, protection level reaches IP40, low power consumption fanless heat dissipation technology, MTBF average trouble-free working time up to 35 years, 5-year warranty.
FEATURE
Gigabit access, SFP fiber port uplink
◇ Support Gigabit Ethernet port and Gigabit SFP port combination, which enables users to flexibly build networking to meet the needs of various scenarios.
◇ Support non-blocking wire-speed forwarding.
◇ Support full-duplex based on IEEE802.3x and half-duplex based on backpressure.
Security
◇ 802.1X authentication.
◇ Port isolation,Storm control.
◇ IP-MAC-VLAN-Port binding.
Strong business processing capability
◇ ERPS/STP/RSTP/MSTP.
◇ Static and dynamic aggregation.
◇ IGMP V1/V2 and IGMP Snooping.
◇ IEEE802.1Q VLAN, flexible VLAN division, Voice VLAN, and QinQ configuration.
◇ QoS, Priority mode based on 802.1P, Port & DSCP, queue scheduling algorithm including EQU, SP, WRR & SP+WRR.
◇ ALC, filter data packet through configuring matching rules, processing operation & time permission, and provide flexible and safe access control.
Easy operation and maintenance management
◇ HTTPS, SSLV3, and SSHV1/V2.
◇ RMON, system log, LLDP, and port traffic statistics.
◇ CPU monitoring, memory monitoring, Ping test, and cable diagnose.
◇ Web management,Telnet, SNMP (V1/V2/V3).
◇ ONV-NMS platform management (local/cloud platform), support mobile APP operation and maintenance
Personalized function extension
◇ IEEE802.3af/at/bt function expansion, the highest support single-port load 90W.
◇ Software customization can be directly upgraded to operation and maintenance terminal host (functions similar to intelligent communication boxes) which can quickly realize low-cost upgrades.
◇ Cloud platform cluster management, seamless connection with third-party monitoring /management platforms.
Rugged shell
◇ Low power consumption, no fan, silent design. Using a 3mm aluminum alloy shell, excellent heat dissipation ensures the stable operation of the product.
DIMENSION
PACKING LIST
PACKING LIST |
CONTENT |
QTY |
UNIT |
DIN Rail AI managed industrial switch |
1 |
SET |
|
User guide |
1 |
PC |
|
Warranty card |
1 |
PC |
TECHNICAL SPECIFICATION
Model |
ONV-IoT7000-SW6G2F-DG |
Interface Characteristics |
|
Fixed Port |
6*10/100/1000Base-T RJ45 ports (Data) 2*100/1000Base-X uplink SFP ports (Data) 1 set V+, V- DC power port (2P Phoenix terminal) |
Ethernet Port |
Port 1-6 support 10/100/1000Base-T auto-sensing,Full/half duplex MDI/MDI-X self-adaption |
Twisted Pair Transmission |
10BASE-T: Cat3,4,5 UTP(≤100 meter) 100BASE-TX: Cat5 or later UTP(≤100 meter) 1000BASE-T: Cat5e or later UTP(≤100 meter) |
SFP Slot Port |
Gigabit SFP optical fiber interface, default matching optical modules (optional order single-mode / multi-mode, single fiber / dual fiber optical module. LC) |
Optical Cable/ Distance |
Multi-mode: 850nm/0 ~ 500M, single-mode: 1310nm/0 ~ 40KM, 1550nm/0 ~ 120KM. |
Chip Parameter |
|
Network Management Type |
L2+ |
Network Protocol |
IEEE802.3 10BASE-T, IEEE802.3i 10Base-T,IEEE802.3u 100Base-TX IEEE802.3ab 1000Base-T, IEEE802.3z 1000Base-X, IEEE802.3x |
Forwarding Mode |
Store and Forward(Full Wire Speed) |
Switching Capacity |
128Gbps |
Forwarding Rate@64byte |
5.95Mpps |
MAC |
8K |
Buffer Memory |
4M |
Jumbo Frame |
9.6K |
CPU |
416M |
DRAM |
1G |
FLASH |
128M |
LED Indicator |
Powe : PWR (Green) , System : SYS (Green) , Network: Link (Green), Fiber port: L/A (Green) |
Reset Switch |
Yes, press and hold the switch for 10 seconds and release it to restore factory settings |
Power Supply |
|
Working Voltage |
DC12V power supply, 2P industrial Phoenix terminal connection, support anti-reverse protection |
Power Consumption |
Standby<8W, Full load<12W |
Power Supply |
No, directly connected to the DC12V power of the monitoring box/ intelligent O&M box |
Physical Parameter |
|
Operation TEMP / Humidity |
-40~+80°C, 5%~90% RH Non condensing |
Storage TEMP / Humidity |
-40~+85°C, 5%~95% RH Non condensing |
MTBF |
>100,000 hours |
Dimension (L*W*H) |
148*102*56mm |
Net /Gross Weight |
<0.6kg / <0.8kg |
Installation |
Wall-mounted, 35mm DIN-rail |
Certification & Warranty |
|
Lightning Orotection / Protection Level |
Lightning protection: 6KV 8/20us; Protection level: IP40 IEC61000-4-2(ESD):±8kV contact discharge,±15kV air discharge IEC61000-4-3(RS):10V/m(80~1000MHz) IEC61000-4-4(EFT): power cable:±4kV; data cable:±2kV IEC61000-4-5(Surge):power cable:CM±4kV/DM±2kV; data cable:±4kV IEC61000-4-6(radio frequency transmission):10V(150kHz~80MHz) IEC61000-4-8(power frequency magnetic field):100A/m;1000A/m ,1s to 3s IEC61000-4-9(pulsed magnet field):1000A/m IEC61000-4-10(damped oscillation):30A/m 1MHz IEC61000-4-12/18(shockwave):CM 2.5kV,DM 1kV IEC61000-4-16(common-mode transmission):30V; 300V,1s FCC Part 15/CISPR22(EN55022):Class B IEC61000-6-2(Common Industrial Standard) |
Mechanical Properties |
IEC60068-2-6 (anti vibration) IEC60068-2-27 (anti shock) IEC60068-2-32 (free fall) |
Certification |
CE mark, commercial; CE/LVD EN60950;FCC Part 15 Class B; RoHS |
Warranty |
5 years, lifelong maintenance. |
Network Management Features |
|
Interface |
IEEE802.3X (Full-duplex) Port temperature protection setting Port green Ethernet Energy-saving setting Broadcast storm control based on port speed The speed limit of the message flow in the access port. The minimum particle size is 64Kbps. |
Layer 3 Features |
L2+ network management ,IPV4/IPV6 management L3 soft routing forwarding, Static route/Default route @ 128 pcs, APR @ 1024 pcs |
VLAN |
4K VLAN based on port, IEEE802.1q VLAN based on the protocol VLAN based on MAC Voice VLAN, QinQ configuration Port configuration of Access, Trunk, Hybrid |
Port Aggregation |
LACP, Static aggregation Max 4 aggregation groups and 8 ports per group. |
Spanning Tree |
STP (IEEE802.1d),RSTP (IEEE802.1w),MSTP (IEEE802.1s) |
Industrial Ring Network Protocol |
G.8032 (ERPS),Recovery time less than 20ms 250 Ring at most, Max 250 devices per ring. |
Multicast |
MLD Snooping v1/v2,Multicast VLAN IGMP Snooping v1/v2, Max 1024 multicast groups, Fast log out |
Port Mirroring |
Bidirectional data mirroring based on port |
QoS |
Flow-based Rate Limiting Flow-based Packet Filtering 8*Output queues of each port 802.1p/DSCP priority mapping Diff-Serv QoS,Priority Mark/Remark Queue Scheduling Algorithm (SP, WRR, SP+WRR) |
ACL |
Port-based Issuing ACL,ACL based on port and VLAN L2 to L4 packet filtering, matching first 80 bytes message. Provide ACL based on MAC, Destination MAC address, IP Source, Destination IP, IP Protocol Type, TCP/UDP Port, TCP/UDP Port Range, and VLAN, etc. |
Security |
IP-MAC-VLAN-Port binding ARP inspection,Anti-DoS attack AAA & RADIUS,MAC learning limit Mac black holes,IP source protection IEEE802.1X & MAC address authentication Broadcast storm control,Backup for host datum SSH 2.0,SSL,Port isolation,ARP message speed limit User hierarchical management and password protection |
DHCP |
DHCP Client,DHCP Snooping,DHCP Server,DHCP Relay |
Management |
One-key recovery Cable Diagnose,LLDP Web Management (HTTPS) NTP,System work log,Ping Test CPU instant utilization status view Console/AUX Modem/Telnet/SSH2.0 CLI Download & Management on FTP, TFTP, Xmodem, SFTP,SNMP V1/V2C/V3 ONV NMS - smart network management system platform(LLDP+SNMP) |
System |
Category 5 Ethernet network cable Web browser: Mozilla Firefox 2.5 or higher, Google browser chrome V42 or higher, Microsoft Internet Explorer10 or later; TCP/IP, network adapter, and network operating system (such as Microsoft Windows, Linux, or Mac OS X) installed on each computer in a network |